Previous Article Return to overview
CoolControl Cooling Tower Controller

CoolControl Cooling Tower Controller

The cooling tower controller DULCOMETER® CoolControl is a measuring and control device based on microprocessor technology offering the highest degree of processing reliability in a broad spectrum of applications. The controller is configurable and so can be individually adapted to your requirements. You choose and pay for what you need.

Advantages

  • Optimum adaptation to processing requirements through different levels of configuration
  • Seamless integration into your processing technology: Variable installation options for sensors and different control options for metering equipment together with blowdown shutter valves and valves.
  • Safety: Threshold value monitoring and adjustable maximum duration of blowdown
  • Simple and easy-to-view user menus in full text via a large LCD display in many languages
  • Large, easy-to-read graphics LCD for measured values, correcting values and information.

Application Areas

  • Cooling tower
  • Air washers
  • Air humidifiers in climatic engineering

Features

  • Blowdown control
  • Metering of a corrosion inhibiting agent
  • Metering of 1 or 2 biocides
  • Daily and 2-weekly timer
  • Forced blowdown and blowdown shutoff
  • Calibration function for the metering pumps
  • Water meter input with adjustable pulse rate
  • Pause input for blowdown shutoff
  • Signal output for temperature-compensated conductivity, 0/4 – 20 mA, galvanically separated
  • Alarm relay for alarm output
  • Adjustable alarm threshold for the measured value of conductivity
  • Wall and panel mount housing
  • Adjustable access code

Besides offering DULCOMETER measurement devices and controllers, ProMinent also offers DULCOTEST fluid conduction sensors and metering pumps to build a complete closed loop system. Measurement, control, dosage and recording, all from one source and optimized to work together.

Technical Data

Parameter Measurement and
Control Range
Resolution Measured Input

Conductive conductivity

0 - 20 µS/cm
0 - 200 µS/cm
0 - 2 mS/cm
0 - 200 mS/cm
0.001 µS/cm Terminal conductive capacity
Inductive conductivity

0 - 200 µS/cm
0 - 2 mS/cm
0 - 200 mS/cm
0 - 2,000 mS/cm

0.01 µS/cm Terminal inductive capacity

Size Value
Accuracy 0.5 % of the measurement range at 77° F (25° C)
Correction variable Temperature via Pt 100
Correction range 32...212° F (0...100° C)
Control

Blowdown between two threshold values with forced blowdown prior to biocide metering

Adjustable outputs

1 Reed contact for biocide 1

1 Reed contact for corrosion inhibitor

1 power relay for biocide 21 power relay for blowdown valve

or

1 Reed contact for biocide 1

1 Reed contact for corrosion inhibitor

1 adjustable motor output for blowdown valve

Analog outputs

1 analog output (0/4…20 mA) galvanically separated, max load 600 W) as measured value

Alarm relay 250V ~3 A, 700 VA, changeover contact type
Electrical connection 24 V AC/DC / 115 V~ /230 V~ ±10 %
Protection class

Wall mounted: IP 65

Panel mounted: IP 54

Ambient temperatures

Wall mounted: 23...104° F (-5...40 °C non-condensing)

Panel mounted: 32...104° F (0...40 °C non-condensing)

Dimensions (WxHxD)

Panel mounted: 3.78" x 3.78" x 5.51" (96 x 96 x 140 mm)

Wall mounted: 7.44" x 7.87" x 2.99" (189 x 200 x 76 mm)