From small to large - extremely flexible for all water treatment systems
Application-specific software modules are available for the DULCOMETER diaLog X to make configuration to the process as simple and precise as possible, without the need for programming. Using freely configurable function blocks, the DULCOMETER diaLog X can map almost any customer application.
The controller is scalable and manages several systems simultaneously and decentrally. The combination of main and satellite unit increases flexibility. The main unit can be extended by up to two satellite units. This makes the DULCOMETER diaLog X suitable for almost all customer applications in water treatment, even on a large scale.
The system can be conveniently controlled remotely thanks to the wide range of communication options. A customisable web server A web server is a software application executed by the DULCOMARIN® II. more in the glossary enables easy management, tracking and visualisation of data, even remotely by DULCONNEX.
Your benefits
- High flexibility thanks to a modular design and easily expandable I/O (input/output) modules, which allow for the connection of additional sensors and pumps.
- Expandable by up to two satellite units for additional inputs and outputs, allowing for the connection of additional sensors and pumps.
- Intuitive operation via HMI (Human Machine Interface) using an easy-to-read industrial display and rugged buttons for standard commands, such as calibration and monitoring.
- Easy configuration of process settings as well as monitoring and visualization of process data via a web server with freely configurable and preconfigured software modules
- Comprehensive overview and control of processes, such as cooling tower processes: All process data and alarms can be transmitted to the process control system via fieldbuses such as Modbus RTU.
- Advanced communication options: Various network protocols, such as FTP, enable remote access and data management via Wi-Fi and LAN (Ethernet).
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Potable water and sewage treatment
- Wastewater treatment
- Industrial and process water treatment
- Food and Beverage process water treatment
Technical Details
Comprehensive inputs and outputs
- Up to 24 flexible sensor inputs and mA outputs (8 per device), e.g. CTFS sensor, linear polarisation resistor (LPR) corrosion sensor
- Up to 30 output relays and pulse outputs (10 per device) to control pumps and other actuators
- Up to 24 digital inputs (8 per device) to control level switches, water meters and remote switches
Communication options
- In-built Modbus RTU and via gateways (BACnet, Modbus TCP, PROFINET)
- Web interface via Wi-Fi and Ethernet, FTP server. The client interface is an intuitive remote control via a Wi-Fi or network connection to your PC or smartphone, e.g. for configuration settings or setpoint settings.
- Configurable and managed via DULCONNEX.
Technical Data
|
Measured variables and measuring ranges | Conductivity: with the digital sensor CTFS via serial module D1: 0.1 - 10 mS/cm via conductivity module L3 depending on the sensor used (LMP, LFT): 50 μS/cm - 20 mS/cm via mA module AA with the inductive Conductivity Sensors ICT: 8 to 2 mS/cm, 20 mS/cm, 200 mS/cm Connection type mV: pH: 0.00 ... 14.00 ORP voltage: -1500 ... +1500 mV Connection type mA (amperometric variables, measuring ranges according to the sensors: Bromine Chlorine Chlorine dioxide Chlorite Fluoride dissolved Oxygen Ozone Peracetic Acid Hydrogen peroxide Temperature: via Pt 100/Pt 1000, measuring ranges 32 °F ... 302 °F (0 ... 150 °C) |
Inputs and outputs | Inputs 8 digital control inputs for contact water meters, flow switches, and pause for interlocking 4 plug-in module slots per unit for 2-channel serial sensor input module (for digital sensors) 2-channel conductivity input module 2-channel mV input module 2-channel mV/mA input module 2-channel mA input module Outputs 2-channel mA output module 6 power relays as changeover contacts, 3 of which are potential-free and 3 voltage-switching 4 pulse frequency outputs for controlling metering pumps |
Resolution | pH: 0.01 pH ORP: 1 mV Amperometric analysis (chlorine etc.): 0.001/0.01 ppm, 0.01 vol. % |
Accuracy | 0.3% based on the full-scale reading |
Temperature compensation | Pt 100/Pt 1000 for pH |
Control characteristic | P/PI/PID control |
Electrical Connection | 100 – 230 V, 50/60 Hz |
Ambient temperature | 23 … 122 °F (-5 … 50 °C) at max. 95% relative air humidity (non-condensing) |
Tests and approvals | CE, MET, UK CA |
Housing material | PC with flame proofing equipment |
Dimensions | 10.87 x 16.69 x 5.39 in (H x W x D) |
Enclosure rating | Wall-mounted: IP 67 |
Field bus connection | Modbus RTU, additional field buses via gateway |
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.