ORLITA DR Rotating Plunger Pump

Capacity range of single-head pump: 0 – 273 l/h, 400 – 76 bar

The plunger metering pump ORLITA DR does not need valves and can therefore be operated within a broad stroke rate range. It is therefore suitable for use with high-viscosity and extremely high-viscosity media of up to 106 mPas within a wide temperature range of -30 °C to +200 °C.

Product description

High Accuracy Metering

The ProMinent Orlita DR is a valveless rotary piston metering pump capable of reaching pressures up to 5,800 psi (400 bar) and flows up to 1,090 gph (4,125 l/h). Fluid is pumped by the combined oscillating and rotating movement of the piston. The valveless design allows accurate metering of highly viscous media up to 1,000,000 cPs.

The DR can also handle fluids containing solids as the slotted piston and the valveless technology allow for solids to move through the pump unobstructed.

Your benefits

Optimum adaptation to processes with high-viscosity and extremely high-viscosity media, even those containing solid fractions:

  • Low-wear and precise operation even at high pressures thanks to the rotary piston with abrasion-resistant / wear-resistant surface coating
  • Valve-free operation guarantees a broad stroke rate range
  • Wide range of uses: Operating pressure of up to 400 bar, temperature range of -30°C to +200°C
  • Pumping direction can be selected depending on the fitting position of the piston
  • A reverse suction effect can be set in a continuously variable manner by rotating the pump head around its longitudinal axis
  • Power end configuration ideal for installation in any position (vertical or horizontal)
  • Excellent hydraulic efficiency
  • 2 different gear ratios are available
  • Customised designs are available on request

Technical Details

  • DR 15 - stroke length: 0-15 mm, rod force: 1800 N
  • DR 150 - stroke length: 0-32 mm, rod force: 15000 N
  • Stroke length adjustment range: 0 – 100% in operation and idle
  • Stroke length adjustment: manually using manual adjustment wheel and scaled display (optionally with electric actuator or control drive)
  • The dosing precision is better than ± 0.5 % within the 10 – 100% stroke length range under defined conditions and with correct installation
  • Wetted materials: Stainless steel, special designs are available on request
  • A wide range of power end/drive versions is available: Three-phase standard AC motors, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
  • Degree of protection: IP 55
  • Temperature range -30°C to +200°C
  • The play between the piston and cylinder responsible for the sealing effect is selected depending on the viscosity
  • Turret on the rear head end, either designed as a circular collecting vessel for leaks or exposed to a sealing medium
  • The turret is sealed by elastomer lip sealing rings

Technical data for ORLITA DR 15 single-head pump 50 Hz

Plunger Ø

Theor. stroke volume

Max. capacity (theo.) in gph | l/h at strokes/min (50 Hz)

Max. pressure

Nominal diameter

58

77

116

inch

ml/stroke

gph | l/h

gph | l/h

gph | l/h

psi

0.28

0.58

0.53 | 2.0

0.71 | 2.7

1.06 | 4.0

5,802

0.47

1.70

1.56 | 5.9

2.09 | 7.9

3.12 | 11.8

2,306

3/16"

0.71

3.82

3.51 | 13.3

4.68 | 17.7

7.03 | 26.6

1,030

1/4"

0.98

7.36

6.76 | 25.6

9.01 | 34.1

13.53 | 51.2

537

1/2"

1.42

15.27

14.03 | 53.1

18.71 | 70.8

28.08 | 106.3

261

1"

Technical data for ORLITA DR 150 single-head pump 50 Hz

Plunger Ø

Theor. stroke volume

Theoretical pump capacity in l/h at strokes/min

Max. pressure

Nominal diameter

58

77

97

116

145

inch

ml/stroke

gph | l/h

gph | l/h

gph | l/h

gph | l/h

gph | l/h

psi

0.47

3.62

3.33 | 12.6

4.44 | 16.8

5.55 | 21.0

6.66 | 25.2

8.32 | 31.5

5,802

3/16"

0.71

8.14

7.48 | 28.3

9.99 | 37.8

12.47 | 47.2

14.98 | 56.7

18.71 | 70.8

5,802

3/16"

0.98

15.71

14.45 | 54.7

19.23 | 72.8

24.04 | 91.0

28.88 | 109.3

36.12 | 136.7

3,626

1/2"

1.42

32.57

29.96 | 113.4

39.89 | 151.0

49.88 | 188.8

59.89 | 226.7

74.87 | 283.4

2,132

1"

Note

All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.

Abridged presentation of our complete product range. Other types on request.

Downloads for ORLITA DR Rotating Plunger Pump

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

High Accuracy Metering

The ProMinent Orlita DR is a valveless rotary piston metering pump capable of reaching pressures up to 5,800 psi (400 bar) and flows up to 1,090 gph (4,125 l/h). Fluid is pumped by the combined oscillating and rotating movement of the piston. The valveless design allows accurate metering of highly viscous media up to 1,000,000 cPs.

The DR can also handle fluids containing solids as the slotted piston and the valveless technology allow for solids to move through the pump unobstructed.

Your benefits

Optimum adaptation to processes with high-viscosity and extremely high-viscosity media, even those containing solid fractions:

  • Low-wear and precise operation even at high pressures thanks to the rotary piston with abrasion-resistant / wear-resistant surface coating
  • Valve-free operation guarantees a broad stroke rate range
  • Wide range of uses: Operating pressure of up to 400 bar, temperature range of -30°C to +200°C
  • Pumping direction can be selected depending on the fitting position of the piston
  • A reverse suction effect can be set in a continuously variable manner by rotating the pump head around its longitudinal axis
  • Power end configuration ideal for installation in any position (vertical or horizontal)
  • Excellent hydraulic efficiency
  • 2 different gear ratios are available
  • Customised designs are available on request

Application

Technical Data

Downloads

Contact us

ProMinent Fluid Controls Ltd.


»We are always available to help. Don't hesitate to contact us.«

+1 888 709 9933 

ProMinent Newsletter - receive latest news, customized for you! subscribe now