Suggestions

Bypass Fittings for Sensors

Your sensors are ideally accommodated in the bypass fitting. This fitting ensures optimum measuring conditions.

Product description

In-flow measurement

We offer a range of bypass fittings for specific integration into processes. They hold potentiometric and amperometric sensors as well as conductivity sensors and ensure optimum operating conditions for measurement.

Sensor bypass armature Modular BAMa

Your Benefits

  • The sensors can be quickly and easily fitted and dismantled thanks to bayonet fittings.
  • All parts requiring maintenance can be cleaned very well as they are easy to access without tools.
  • Water consumption is minimised to just 5 l/h for flow-dependent sensors under ideal measurement conditions.
  • The good particle mobility allows the bypass armature to be used in an even wider range of applications.
  • Construction and material permit temperatures of up to 70 °C at a max. pressure of 3 bar, making it even more flexible to use.
  • Thanks to higher pressure levels of up to 7 bar at 20 °C, sample water can return to the process, where permitted.
  • The BAMa provides numerous options for setting optimum measurement conditions.

Technical Data

ApplicationDrinking water or similar with sample water drainedWater from Pool & Wellness or similar with sample water returned to processIndustrial water or similar with a solids content and higher temperature and pressure requirements
Flow through the BAMa fiiting5…25 l/h20…60 l/h20…100 l/h
Minimum priming pressure without flow limiter and with clean filter, for a total of 9 modules0.025 bar0.05 bar0.5 bar
Minimum priming pressure with flow limiter and with clean filter, for a total of 9 modules1.5 bar1.5 bar2.0 bar
Maximum operating pressure7.0 bar at 20 °C7.0 bar at 20 °C7.0 bar at 20 °C
Maximum operating temperature60 °C at 3.5 bar60 °C at 3.5 bar70 °C at 3.0 bar
Surrounding temperature-10…60°C-10…60°C-10…60°C
Particle mobility (proved with non-agglomerating, non-sedimentary model particles)< 300 µm< 300 µm< 1,000 µm

Bypass fitting type DLG III

To hold 2 sensors (conductivity, Pt 100, pH or ORP sensors) with PG 13.5 screw-in thread plus one sensor with R 1" screw-in thread (amperometric sensors) with integrated stainless steel pin as liquid reference potential.

On the inlet side, the DLG III is equipped with a plastic ball valve for blocking and adjusting the sample water flow.

Material

In-line probe housing: PVC hard
Clear cup: Polyamide
Ball valve: PVC hard

Max. pressure

1.0 bar

Max. temperature

55 °C

Typical applications

Cooling water, slightly contaminated wastewater, turbid water, no sludge.

Version

Max. temperature

Order no.

°C

DLG III A with PVC hose connectors

for PE line Ø 8/5 mm

55

914955

DLG III A with flushing connector and PVC hose connection

for PE line Ø 8/5 mm

55

1029096

DLG III B with PVC adhesive connectors

for pipe connection Ø 16 DN 10

55

914956

Assembly kit for fitting amperometric sensors

55

815079

DLG Sampling Water Cup

Order no.

DLG III sampling water cup with back flush device

1029095

DLG IV Type In-Line Probe Housing

To hold 4 sensors (pH, ORP, Pt 100, conductivity) with PG 13.5 screw-in thread. With integrated stainless steel rod as liquid reference potential. Angle for wall mounting.

Material

In-line probe housing: PVC hard or PP

Clear cup: Polyamide

Max. pressure

1.0 bar

Connection for sample water line

Union with d 16/DN 10 insert

Version

Max. temperature

Order no.

°C

DLG IV PP

for Ø 16/DN 10 pipe work connector

80

1005331

DLG IV PVC

for Ø 16/DN 10 pipe work connector

55

1005332

  • pk_6_070

Downloads for Bypass Fittings for Sensors

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

In-flow measurement

We offer a range of bypass fittings for specific integration into processes. They hold potentiometric and amperometric sensors as well as conductivity sensors and ensure optimum operating conditions for measurement.

Technical Data

Downloads

Contact us

ProMinent Fluid Controls Ltd.


»We are always available to help. Don't hesitate to contact us.«

+1 888 709 9933 

Matching Products

pH measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Control, regulate and monitor chemical processes with the aid of precise measured values.

more

Hydrogen peroxide measurement with DULCOTEST sensors: Efficient and reliable determination of the concentration of hydrogen peroxide - can be used in a wide range of applications.

more

The application-based DULCOTEST sensors for free chlorine deliver precise measured values and a high degree of monitoring and process reliability in any disinfection application.

more

Temperature measurement with DULCOTEST sensors: Can be used for direct temperature measurement or temperature compensation during measurement of pH, fluoride, conductivity, chlorine dioxide or hydrogen peroxide.

more

Chlorite measurements with DULCOTEST sensors in disinfection processes involving chlorine dioxide – high process reliability guaranteed.

more

Disinfection of swimming pool water with the application-optimised DULCOTEST sensors for total available chlorine - exact measured values and high process reliability guaranteed.

more

Widely used sensor for the measurement of oxygen dissolved in water above 0.1 ppm to oxygen saturation. For installation in standard immersion pipes or in the bypass line of the process flow. Use in aeration tanks of clarification plants, waterworks, in fish breeding or to monitor surface water. Minimal maintenance due to visual measuring principle.

more

Bromine measurement with DULCOTEST sensors: Safe metering in disinfection processes with bromine. The robustness of the sensors makes them suitable for a very wide range of water qualities.

more

ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Can be used in water treatment or industrial process waters with strict requirements.

more

Reliably measure total chlorine with the versatile DULCOTEST sensors for total chlorine. Accurate measured values and a high degree of monitoring and process reliability are guaranteed.

more

Accurate measurement of fluoride with DULCOTEST sensors in the monitoring of potable water and wastewater, suitable for pH values up to 9.5.

more

Chlorine dioxide measurement with DULCOTEST sensors offers precise, reliable, application-specific measured values in real-time for all oxidation and disinfection tasks.

more

Measuring ozone in oxidation and disinfection applications: DULCOTEST sensors offer precise, reliable, application-specific measured values in real-time.

more

Measurement of peracetic acid concentration with DULCOTEST sensors: Precise and reliable for disinfection in safety-sensitive applications in the food, pharmaceutical and medical industries. Can also be used in wastewater treatment.

more

Conductivity sensors for optimum process integration: DULCOTEST sensors meet a wide range of measuring requirements and allow the best solution to any given measuring task to be achieved.

more

News and Events

ProMinent Newsletter - receive latest news, customized for you! subscribe now