Suggestions

DULCOTEST sensors for total available chlorine

Graduated measuring ranges 0.01 – 10 mg/l

Disinfection of swimming pool water with the application-optimised DULCOTEST sensors for total available chlorine - exact measured values and high process reliability guaranteed.

Product description

Reliable online measurement of total available chlorine – with DULCOTEST sensors.

Total available chlorine Chlorine bound to (iso)cyanic acid/isocyanurate and the free (effective) chlorine resulting from it. more in the glossary is also known as 'stabilised chlorine' and is used to prevent premature decomposition by sunlight in the disinfection of swimming pool water, particularly in outdoor pools. This mainly includes compounds such as derivatives of tri-chloro(iso)cyanuric acid. After it has been metered into the water to be treated, it forms free chlorine and also (iso)cyanuric acid containing chlorine. The sensor measures both compounds, which are designated as total available chlorine Chlorine bound to (iso)cyanic acid/isocyanurate and the free (effective) chlorine resulting from it. more in the glossary.

The innovative diaphragm-covered DULCOTEST sensor for total available chlorine Chlorine bound to (iso)cyanic acid/isocyanurate and the free (effective) chlorine resulting from it. more in the glossary CGE3 is optimised for controlling the disinfection of swimming pool water with derivatives of chloro(iso)cyanuric acid. The sensor can also be used simultaneously with in-line chlorine electrolysis Chlorine and sodium hydroxide are produced in-situ in electrolysis by passing an electric ... more in the glossary processes without disturbance from the by-products generated.

Your benefits

  • Sensor for total available chlorine, also suitable for the combination of in-line electrolysis with derivatives of chloro(iso)cyanuric acid
  • Can also be used as a sensor for free chlorine without interference caused by the presence of cyanuric acid
  • Precise, real-time amperometric measurement for efficient process control (short response time)
  • Amperometric measuring eliminates interference caused by turbidity or colouration
  • Stable zero point
  • Integrated temperature compensation eliminates interference caused by influence of temperature

Field of application

The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.

  • Control of total available chlorine in swimming pools, especially outdoor pools.

    Technical Details

    Total available chlorine

    • CGE 3-mA
    • pH: 5.5 … 9.5
    • Temperature: 5 … 45 ºC

    Sensor for total available and free chlorine CGE 3-mA

    Sensor for total available chlorine, such as derivatives of chloro(iso)cyanuric acid, without disturbance when used in swimming pools where disinfection is provided by electrolysis processes. Also suitable for use as a sensor for free chlorine. For operation with controllers with 4-20 mA input

    Your Benefits

    • Measured variable: total available chlorine, for instance disinfectant with organic chlorine, such as derivatives of chloro(iso)cyanuric acid
    • Measured variable: free chlorine without interference with the presence of cyanuric acid
    • Gold electrode to prevent faults by products from electrolysis processes where the electrodes are immersed directly into the sample water (without diaphragm)
    • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
    • Hydrophilic diaphragm guarantees the permeability of chloro(iso)cyanuric acid derivatives towards the measuring electrodes
    • The special reaction system of the electrolyte allows the total available chlorine to be determined and use at a high pH of up to 9.5

    Measured variable

    Free chlorine and total available chlorine: Total of organically bound chlorine (e.g. bound to cyanuric acid) and free chlorine

    Reference method

    DPD1

    pH-range

    5.5…9.5

    Temperature

    5…45 °C

    Max. pressure

    3.0 bar

    Flow

    DGMa, DLG III: 30...60 l/h
    BAMa: 5...100 l/h (depending on design)

    Supply voltage

    16...24 V DC (2-wire)

    Output signal

    4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated

    Selectivity

    total available chlorine and free chlorine as against combined chlorine (chloramines)

    Disinfection process

    Disinfectants with organic chlorine, e.g. based on cyanuric acid, chlorine gas, hypochlorite, electrolysis

    Process integration

    Bypass: open sample water outlet

    Sensor fitting

    BAMa, DGMa, DLG III

    Controllers

    D1C, DAC, AEGIS II, AEGIS X

    Typical applications

    Swimming pool water; combined disinfection processes with chloro(iso)cyanuric acid derivatives and electrolysis. Water of a similar quality to potable water with a higher pH of up to 9.5.

    Resistance to

    Surfactants, cyanuric acid

    Measuring principle, technology

    Amperometric, 2 electrodes, diaphragm-covered

    Measuring range

    Order no.

    CGE 3-mA-2 ppm

    0.02…2.0 mg/l

    1047959

    CGE 3-mA-10 ppm

    0.10…10.0 mg/l

    1047975

    A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

    Sensor for total available and free chlorine CGE 3-CAN

    Sensor for total available chlorine, such as derivatives of chloro(iso)cyanuric acid when used in swimming pools. Also suitable for use as a sensor for free chlorine. For use on controllers with CAN-bus connection

    Your Benefits

    • Measured variable: total available chlorine, for instance disinfectant with organic chlorine, such as derivatives of chloro(iso)cyanuric acid
    • Measured variable: free chlorine without interference with the presence of cyanuric acid
    • Gold electrode to prevent faults by products from electrolysis processes where the electrodes are immersed directly into the sample water (without diaphragm)
    • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
    • Hydrophilic diaphragm guarantees the permeability of chloro(iso)cyanuric acid derivatives towards the measuring electrodes
    • The special reaction system of the electrolyte allows the total available chlorine to be determined and use at a high pH of up to 9.5
    • Operation on the CAN-bus with all the associated benefits

    Measured variable

    Free chlorine and total available chlorine: Total of organically bound chlorine (e.g. bound to cyanuric acid) and free chlorine

    Reference method

    DPD1

    pH-range

    5.5…9.5

    Temperature

    5…45 °C

    Max. pressure

    3.0 bar

    Flow

    DGMa, DLG III: 30...60 l/h
    BAMa: 5...100 l/h (depending on design)

    Supply voltage

    Via CAN interface (11 – 30 V DC)

    Output signal

    Uncalibrated, temperature compensated, electrically isolated

    Selectivity

    total available chlorine and free chlorine as against combined chlorine (chloramines)

    Disinfection process

    Disinfectants with organic chlorine, e.g. based on cyanuric acid, chlorine gas, hypochlorite, electrolysis

    Process integration

    Bypass: open sample water outlet

    Sensor fitting

    BAMa, DGMa, DLG III

    Controllers

    DULCOMARIN 3, DULCOMARIN II with hardware before 06.02.2014 from software version 3027 or later, with hardware after 06.02.2014 from software version 3033 or later

    Typical applications

    Swimming pool water, disinfection processes with chloro(iso)cyanuric acid derivatives and electrolysis. Water of a similar quality to potable water with a higher pH of up to 9.5.

    Resistance to

    Surfactants, cyanuric acid

    Measuring principle, technology

    Amperometric, 2 electrodes, diaphragm-covered

    Measuring range

    Order no.

    CGE 3-CAN-10 ppm

    0.01…10.0 mg/l

    1047977

    A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

    Downloads for DULCOTEST sensors for total available chlorine

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Reliable online measurement of total available chlorine – with DULCOTEST sensors.

    Total available chlorine Chlorine bound to (iso)cyanic acid/isocyanurate and the free (effective) chlorine resulting from it. more in the glossary is also known as 'stabilised chlorine' and is used to prevent premature decomposition by sunlight in the disinfection of swimming pool water, particularly in outdoor pools. This mainly includes compounds such as derivatives of tri-chloro(iso)cyanuric acid. After it has been metered into the water to be treated, it forms free chlorine and also (iso)cyanuric acid containing chlorine. The sensor measures both compounds, which are designated as total available chlorine Chlorine bound to (iso)cyanic acid/isocyanurate and the free (effective) chlorine resulting from it. more in the glossary.

    The innovative diaphragm-covered DULCOTEST sensor for total available chlorine Chlorine bound to (iso)cyanic acid/isocyanurate and the free (effective) chlorine resulting from it. more in the glossary CGE3 is optimised for controlling the disinfection of swimming pool water with derivatives of chloro(iso)cyanuric acid. The sensor can also be used simultaneously with in-line chlorine electrolysis Chlorine and sodium hydroxide are produced in-situ in electrolysis by passing an electric ... more in the glossary processes without disturbance from the by-products generated.

    Your benefits

    • Sensor for total available chlorine, also suitable for the combination of in-line electrolysis with derivatives of chloro(iso)cyanuric acid
    • Can also be used as a sensor for free chlorine without interference caused by the presence of cyanuric acid
    • Precise, real-time amperometric measurement for efficient process control (short response time)
    • Amperometric measuring eliminates interference caused by turbidity or colouration
    • Stable zero point
    • Integrated temperature compensation eliminates interference caused by influence of temperature

    Application

    Technical Data

    Downloads

    Contact us

    ProMinent Fluid Controls Ltd.


    »We are always available to help. Don't hesitate to contact us.«

    +1 888 709 9933 

    Matching Products

    ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Can be used in water treatment or industrial process waters with strict requirements.

    more

    The solenoid-driven diaphragm metering pump gamma incorporates a wealth of eX cellent ingenuity! With integrated pressure measurement, it ensures the smooth running of your metering process. The gamma/ X is ideal for all metering work involving liquid media.

    more

    Do you wish for a simple controller for water analysis? One that is easy to operate and with which you can freely select between all common measured variables per channel? There is one: our all-rounder DULCOMETER diaLog DACb! What is more, it is Ethernet-/LAN-capable and can be ideally integrated into existing networks.

    more

    The measuring and control system DULCOMARIN 3 is your digital link to the technology of the future. It controls the entire range of swimming pools – from adventure pools to private pools – and is used as a multi-pool system for up to 16 filter circuits.

    more

    Photometers measure nearly all disinfectants and the pH value based on the photometric principle. They are portable, compact and make safe, simple measurement possible.

    more

    Electrolysis systems of type CHLORINSITU V take the place of the chlorine gas system in the swimming pool and only need salt, water and electricity to do so.

    more

    ProMinent Newsletter - receive latest news, customized for you! subscribe now