Economical metering pump solutions!
The Concept b mounts easily onto a tank or wall bracket. Adjustment of the pump capacity is via the stroke length in the range of 10-100 % or can be set at 1 of the 4 stroke frequency settings. This gives an adjustment ratio of 40:1.
Your benefits
- NSF 61/50 approved
- Low cost opens up opportunities in the most basic applications
- PVDF wetted ends eliminate compatibility concerns
- Integral bleed valve prevents "loss of prime"
- Lowest maintenance costs in its class
- External control via dry contact pulse (1:1)
- Wetted end materials: PP, Acrylic/PVC or PVDF
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Swimming pools
- Spas, fountains and spray pads
- Cooling towers
- Boiler feed applications
- General Chlorination
- Municipal and industrial wastewater
- Water disinfection
- Biocide feed
- "Pump on a drum" applications
Technical Data
Pump type | Capacity at max. back pressure | Pump capacity at max. back pressure | Stroke rate | Suction lift | Connector size o Ø x i Ø | Shipping weight |
---|
| gph | l/h | psi | ml/stroke | Strokes/min | ft | m WC | inch | lb | kg |
---|
CNPb 1000 | 0.18 | 0.7 | 145 | 0.07 | 180 | 20 | 6 | 1/4 x 3/16 | 4 | 1.8 |
CNPb 1601 | 0.29 | 1.1 | 232 | 0.10 | 180 | 20 | 6 | 1/4 x 3/16 | 4 | 1.8 |
CNPb 1002 | 0.63 | 2.4 | 145 | 0.19 | 180 | 16 | 5 | 1/4 x 3/16 | 4 | 1.8 |
CNPb 1003 | 0.79 | 3.0 | 145 | 0.21 | 240 | 16 | 5 | 1/4 x 3/16 | 4 | 1.8 |
CNPb 0704 | 1.06 | 4.0 | 102 | 0.41 | 180 | 13 | 4 | 1/4 x 3/16 | 4 | 1.8 |
CNPb 0705 | 1.37 | 5.2 | 102 | 0.36 | 240 | 13 | 4 | 1/4 x 3/16 | 4 | 1.8 |
CNPb 0309 | 2.38 | 9.0 | 44 | 0.83 | 180 | 20 | 6 | 3/8 x 1/4 | 4 | 1.8 |
CNPb 0215 | 4.33 | 16.4 | 22 | 1.45 | 180 | 5 | 1.5 | 3/8 x 1/4 | 4 | 1.8 |
Note: Above capacities and suction lift refer to pumps tested on water at 115 VAC, 60 Hz, and an ambient temperature of 70 °F (20 °C). Higher specific gravity fluids will reduce suction lift. Capacities will be slightly reduced from published ratings if pumps are skid mounted)
External pulse contact retrofit available as an option (P/N 1046731)
NSF 50 certification only applies to NPB0 & NPB2 liquid ends
Materials in Contact with the Medium
| Pump head | Valves | O-rings | Balls |
PPE | Polypropylene | Polypropylene | EPDM | Ceramic |
PPB | Polypropylene | Polypropylene | Viton® | Ceramic |
NPE | Acrylic | PVC | EPDM | Ceramic |
NPB | Acrylic | PVC | Viton® | Ceramic |
PVT | PVDF | PVDF | PTFE | Ceramic |
Pump diaphram with PTFE-coating.
Note: Viton® is a registered trademark of DuPont Dow Elastomers.